AIRCYCLER® G2 FURNACE FAN TIMER + FANCONNECT™ SWITCH
WHOLE HOUSE MECHANICAL VENTILATION SYSTEM

Product Information

Printable Information Sheet - g2

Printable Information Sheet - FanConnect

Instructional Materials

AirCycler g2 Testing and Flow Measuring Video
Setup Simulator

User's Guide
Installation Training Guide
Installation Testing Guide
Quick Calculated Time Setup
Quick Calculated Flow Setup
Homeowner Quick Guide

Quick Links

Shop AirCycler® g2 Products

Schematics & Literature




The AirCycler® g2 System is the industry’s most efficient and economical solution for meeting all whole house mechanical ventilation standards. By maximizing the efficiency of central furnace fan integrated ventilation - using a home’s regular heating and cooling cycles to provide supply ventilation - and exhaust fan ventilation, the AirCycler® g2 System delivers fresh air throughout the home with precise control and energy savings. 

VIDEO


Test the 3 simplest, quickest methods to ventilate any home: exhaust only (1:26), supply only (5:02), and exhaust + supply (8:51) using a G2 controller


FEATURES & BENEFITS

  • Hybrid whole house/exhaust ventilation system
  • Lowest HERS score
  • Recommended by building scientists and engineers
  • Direct replacement for AirCycler® FRV
  • Works with most 24VAC dampers
  • Can control a 110VAC exhaust fan
  • Features programmable hours of operation
  • Available with rangehood exhaust tie-in and temperature control
 AirCycler g2

PRODUCT DETAILS


WHAT IS IT?

The complete AirCycler® g2 Whole House Mechanical Ventilation System includes the AirCycler® g2 Furnace Fan Timer, FanConnect™ Bath/Fan Light Switch with remote fan control, and a motorized fresh air damper (available in four sizes). This system provides both whole house supply and exhaust ventilation.

HOW DOES IT WORK?
AirCycler g2 Setup Options
During installation, ventilation requirements are set by entering the measured airflow and airflow required by code (Calculated Flow Setup), or by entering the desired amount of ventilation per hour (Calculated Time Setup).

The AirCycler® g2 Furnace Fan Timer is integrated with the home’s central furnace fan so that any time the central fan is turned on by the thermostat to provide heating or cooling, the AirCycler® g2 opens the motorized damper to let in a measured amount of fresh air. The fresh air is then distributed uniformly throughout the home through the existing ductwork. When ventilation requirements are met, the damper is closed to prevent over-ventilation.

By running the ventilation system at the same time as the home’s regular heating and cooling cycles, the AirCycler® g2 System saves on additional utility costs.

WHAT MAKES THE AIRCYCLER® G2 DIFFERENT?

Through a patented algorithm the AirCycler® g2 logs the ventilation time elapsed during heating or cooling cycles and compares it with the total ventilation requirements set during installation. Should regular heating and cooling cycles not run long enough to meet the desired or required ventilation, the AirCycler® g2 can turn on the smaller and more economical bathroom exhaust fan (or other exhaust fan) via the FanConnect™ Switch. With no need to run the large central fan to provide additional ventilation, homeowner complaints of cold air or noisy operation are eliminated and efficiency is drastically improved.

With basic exhaust-only ventilation solutions, stale air is being exhausted out but there is no known source of where the new, fresh air is being pulled into the home. With the AirCycler® g2, the motorized fresh air damper is opened any time the exhaust fan is on, providing a known, healthy source of fresh air.

Balanced Ventilation When used with the FanConnect™ and an exhaust fan, setting the AirCycler® g2 to Slave Mode will give you balanced whole house ventilation.

SPECIFICATIONS

AirCycler® g2 Furnace Fan Timer
Operating Voltage: 24 VAC
(up to 30 VAC max)
Current Draw: 0.07 Amps

Motorized Fresh Air Damper
Operating Voltage: 24VAC (up to 30 VAC max)
Current Draw: 0.07A idle, 0.125A for
15 sec damper transit time
Power Draw (VA): >1W idle, 3W for 15
sec damper transit time
Wiring Requirements: 18 gauge, min 
Includes pigtail and damper plug for wiring
Can be installed in any position
Check damper model before wiring
Wiring for # FAD or # MVCD below

FanConnect™ Switch
Light: 450 Watts @ 120 VAC (blue wire)
Fan: 150 Watts @ 120 VAC (red wire)
Operation: 120 VAC ± 10%
Wiring Requirements:Class 3 rated cable - buy it here
(Learn more about NEC 725.136)






 
AirCycler g2 Wiring

Wiring Schematic - ACG2K (with damper model # FAD)

 

g2-k Wiring Diagram MVCD

Wiring Schematic - ACG2K (with damper model # MVCD)

 

AirCycler® g2 Wiring - 2 Bathrooms, 1 Exhaust Fan

AirCycler® g2 Wiring - 2-Wire Damper

FanConnect™ Wiring - 2 Bathrooms, 2 Exhaust Fans

AirCycler® g2 Wiring - Supply Fan + Exhaust Fan (No AHU)

FanConnect™ Details & Wiring

FanConnect™ Wiring - NEC 725.136 Compliance by Mike Holt

Booster Fan Wiring

Communicating Thermostat Wiring

Carrier Communicating Furnace Wiring

Rating Software Procedure

Please note that in any application, only one (1) FanConnect™ switch can be used with a single AirCycler® g2 controller.


HRV/ERV SYSTEM vs AIRCYCLER® G2 WHOLE HOUSE VENTILATION SYSTEM

Operation Time & Energy Use to Reach 1,800 CF Fresh Air



 
Use the AirCycler® g2 with your existing HVAC system to gain efficiency and save on ventilation costs

 

DAMPER DIMENSIONS




This product may be protected by one or more of the following patents and patents pending: